Thermal-technical calculations (ČSN 73 0540)
We perform thermal engineering calculations, including evaluation according to ČSN 73 0540-2: 2011, especially in the following areas:
- heat transfer coefficient U [W / m2 ∙ K] and thermal resistance R [m2 ∙ K / W],
- equivalent: thermal conductivity λ [W / m ∙ K],
- exteention of water vapor in structures (balance of condensed water vapor),
- complex solution of construction details (thermal bridges and connections),
- internal surface temperatures and decrease in contact temperature of floor structures,
- evaluation of double-walled structures with an open (ventilated) air layer,
- winter and summer stability of rooms.